Overview
The INFICON UL1000 Fab is a mobile dry helium leak detector specifically engineered to meet the stringent requirements of semiconductor manufacturing, cleanrooms, and high-vacuum applications.
Equipped with an integrated dry scroll pump, it guarantees hydrocarbon- and particle-free testing, making it the ultimate solution for leak detection on semiconductor process equipment, vacuum components, and sealed vessels.
Key Features & Benefits
-
Contamination-Free (Dry System): Powered by a high-capacity dry compressing scroll pump (25 m³/h), allowing safe operation in cleanroom environments without any risk of oil contamination.
-
Rapid Response Technology (I·CAL): Features the proprietary I·CAL software algorithm, enabling real-time detection of tiny leaks down to the 10⁻¹¹ and 10⁻¹² mbar l/s range without response delay.
-
Intelligent Background Suppression (iZERO): Automatically suppresses background helium levels to deliver fast, accurate measurements without masking real leaks.
-
Cleanroom-Optimized Design: Engineered airflow prevents disruption to laminar airflow systems in cleanroom setups.
-
User-Friendly Interface: Features an intuitive rotatable display and supports both wired and wireless remote control options (RC1000).
-
Automatic Calibration: An integrated, calibrated internal test leak ensures consistent measurement accuracy before every test cycle.
Testing Modes INFICON UL1000
The ul1000 leak detector offers versatile testing modes to handle various application requirements:
-
Vacuum Mode (Spray Method):
-
GROSS Mode (Inlet P > 15 mbar): Initial test phase for large-volume chambers or high leak rate detection.
-
FINE Mode (Inlet P < 2 mbar): Intermediate mode for detecting medium-range leaks.
-
ULTRA Mode (Inlet P < 0.4 mbar): High-sensitivity mode capable of identifying micro-leaks down to 10⁻¹² mbar l/s.
-
-
Sniffer Mode (Sniffer Probe Method): Designed for overpressure leak testing from the outside using an optional sniffer probe (detectable down to < 5 x 10⁻⁸ mbar l/s).
-
Auto-Sequence / Smart Test Mode: Automatically manages crossover pressures to optimize cycle times for high-throughput testing.
Common Operational Issues & Troubleshooting
Here is a quick troubleshooting guide for common field issues INFICON UL1000:
-
“Helium Background High” Alert:
-
Cause: Elevated ambient helium levels or residual tracer gas from previous test runs.
-
Solution: Enable the iZERO feature to suppress background noise, or purge the system with dry nitrogen gas.
-
-
Slow Pump-Down Time:
-
Cause: Contamination on the inlet flange, worn O-rings, or a major gross leak in the test setup.
-
Solution: Clean the inlet flange seals, inspect O-rings for wear, and verify all connection fittings.
-
-
“Filament Error / Filament Burned” Warning:
-
Cause: Mass spectrometer filament burnout due to extended wear or sudden exposure to atmospheric pressure.
-
Solution: The system will automatically switch to the secondary backup filament. Schedule an ion source assembly replacement soon after.
-
-
Calibration Failed:
-
Cause: Depleted/clogged internal test leak or the system has not reached operating temperature.
-
Solution: Allow the unit a 15–20 minute warm-up period before initiating auto-calibration.
-
Spare Parts & Maintenance
Regular preventive maintenance and genuine replacement parts are recommended to ensure long-term reliability:
-
Routine Maintenance:
-
Daily / Weekly: Clean the inlet flange, inspect O-rings, and run daily calibration checks.
-
Annual Service: Perform routine dry scroll pump service (tip seal replacement) and clean the spectrometer cell.
-
-
Popular Spare Parts & Accessories:
-
Ion Source / Filament Assembly: Long-life dual iridium/yttria-coated filaments.
-
Internal Calibrated Test Leak: Traceable reference leak standard for ISO/QS compliance.
-
Scroll Pump Tip Seal Kit: Wear-and-tear replacement kit to maintain peak vacuum performance.
-
Optional Accessories: Sniffer probes (various hose lengths), RC1000 Remote Control (Wired/Wireless), and TC1000 Test Chamber.
-
Technical Sp ecifications
| Feature / Parameter | Specification |
| Minimum Detectable Leak Rate (Vacuum) | < 5 x 10⁻¹² mbar l/s |
| Minimum Detectable Leak Rate (Sniffer) | < 5 x 10⁻⁸ mbar l/s |
| Detectable Gases | Helium (4He, 3He), Hydrogen (H2) / Mass 2, 3, 4 amu |
| Fore-Vacuum Pump Type | Dry Scroll Pump (25 m³/h) |
| Detector / Mass Spectrometer | 180° Magnetic Sector Field |
| Inlet Connection | DN 25 KF (optional DN 40 KF) |
| Response Time | < 1 second |
| Dimensions & Weight | 1050 x 472 x 987 mm / approx. 110 kg |
Applications
-
Maintenance and quality control in Semiconductor & Fab facilities.
-
Leak checking on vacuum chambers, gas distribution lines, and valves.
-
Testing hermetically sealed electronic packages and components.
-
High-vacuum system manufacturing and laboratory research.